B
37
Register
No.
Function name
Function code
R/W
Monitoring and setting items
Data
resolution
131Fh
Start freq. of active
frequency matching
b030
R/W
0 (frequency at the last shutoff), 1 (maximum
frequency), 2 (set frequency)
-
1320h
Software lock mode
selection
b031
R/W
0 (disabling change of data other than "b031"
when SFT is on), 1 (disabling change of data
other than "b031" and frequency settings
when SFT is on), 2 (disabling change of data
other than "b031"), 3 (disabling change of data
other than "b031" and frequency settings), 10
(enabling data changes during operation)
-
1321h
(Reserved)
-
-
-
-
1322h
Motor cable length
parameter
b033
R/W 5 to 20
-
1323h
Run/power-on warning time
b034 (high)
R/W
0 to 65535
1 [10h]
1324h
b034 (low)
R/W
1325h
Rotation direction
restriction
b035
R/W
0( Enable for both dir)/ 1 (Enable for
forward only)/ 2 (Enable for reverse only)
-
1326h
Reduced voltage start
selection
b036
R/W
0 (minimum reduced voltage start time) to 255
(maximum reduced voltage start time)
-
1327h
Function code display
restriction
b037
R/W
0 (full display), 1 (function-specific display), 2
(user setting), 3 (data comparison display), 4
(basicdisplay), 5(monitor display)
-
1328h
Initial display selection
b038
R/W 001-060
-
1329h
Automatic user parameter
registration
b039
R/W 0 (disabling), 1 (enabling)
-
132Ah
Torque limit selection
b040
R/W
00 (quadrant-specific setting), 01 (switching by
terminal), 02 (analog input)
-
132Bh
Torque limit 1 (fwd-power in
4-quadrant mode)
b041
R/W 0 to 200/255 (no)
1 [%]
132Ch
Torque limit 2 (rev/regen. in
4-quadrant mode)
b042
R/W 0 to 200/255 (no)
1 [%]
132Dh
Torque limit 3 (rev/power in
4-quadrant mode)
b043
R/W 0 to 200/255 (no)
1 [%]
132Eh
Torque limit 4 (fwd/regen. in
4-quadrant mode)
b044
R/W 0 to 200/255 (no)
1 [%]
132Fh
Torque limit LADSTOP
enable
b045
R/W 0 (disabling), 1 (enabling)
-
1330h
Reverse Run protection
enable
b046
R/W 0 (disabling), 1 (enabling)
-
1331h to
1332h
(Reserved)
-
-
-
-
1333h
Dual Rating Selection
b049
R/W 0(CT mode)/1(VT mode)
-
1334h
Controlled deceleration on
power loss
b050
R/W
0 (disabling), 1 (enabling), 2, (nonstop
operation at momentary power failure (no
restoration))
3, (nonstop operation at momentary power
failure (restoration to be done))
-
1335h
DC bus voltage trigger level
of ctrl. decel.
b051
R/W 0 to 10000
0.1 [V]
1336h
Over-voltage threshold of
ctrl. decel.
b052
R/W 0 to 10000
0.1 [V]
1337h
Deceleration time of ctrl.
decel.
b053 (high)
R/W
0.01 to 36000
0.01
[sec.]
1338h
b053 (low)
R/W
1339h
Initial freq. drop of ctrl.
decel.
b054
R/W 0 to 1000
0.01 [Hz]
133Ah to
133Eh
(Reserved)
-
-
-
-
133Fh
Maximum-limit level of
window comparators O
b060
R/W
0. to 100. (lower limit : b061 + b062 *2) (%)
1 [%]
1340h
Minimum-limit level of
window comparators O
b061
R/W
0. to 100. (lower limit : b060 - b062*2) (%)
1 [%]
1341h
Hysteresis width of window
comparators O
b062
R/W
0. to 10. (lower limit : b061 - b062 / 2) (%)
1 [%]
1342h
Maximum-limit level of
window comparators OI
b063
R/W
0. to 100. (lower limit : b064 + b066 *2) (%)
1 [%]
1343h
Minimum-limit level of
window comparators OI
b064
R/W
0. to 100. (lower limit : b063 - b066 *2) (%)
1 [%]
1344h
Hysteresis width of window
comparators OI
b065
R/W
0. to 10. (lower limit : b063 - b064 / 2) (%)
1 [%]
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......