3
53
Software Lock Mode
The software lock function keeps personnel from accidentally changing parameters in
the inverter memory. Use
to select from various protection levels.
The table below lists all combinations of
option codes and the
ON/OFF state of the [SFT] input. Each Check
or Ex
indicates
whether the corresponding parameter(s) can be edited. The
Standard Parameters column below shows access in permitted for
some lock modes. These refer to the parameter tables throughout
this chapter, each of which includes a column titled
Run Mode Edit
as shown to the right.
The marks (Check
or Ex
) under the “Run Mode Edit” column title indicate
whether access applies to each parameter as defined in the table below. In some lock
modes, you can edit only
and the Multi-speed parameter group that includes
,
,
–
, and
(Jog). However, it does not include
, Multi-speed
operation selection. The editing access to
itself is unique, and is specified in the
right-most two columns below.
Lock
Mode
[SFT]
Intelligent
Input
Standard Parameters
and
Multi-Speed
Stop
Run
Stop and Run
Stop
Run
OFF
Run mode
edit access
ON
OFF
Run mode
edit access
ON
(ignored)
(ignored)
(ignored)
High level
access
NOTE: Since the software lock function
is always accessible, this feature is not the
same as password protection used in other industrial control devices. So if you want to
use password function, use parameter
together with the
. See section 4-104 for
detailed explanation of the password function.
Run
Mode
Edit
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......