1
−
−
−
−
9
Item
General Specifications
Output
signal
Intelligent output
terminal
48 functions assignable
RUN
RUN
RUN
RUN (run signal), FA1~FA5
FA1~FA5
FA1~FA5
FA1~FA5 (frequency arrival signal), OL,OL2
OL,OL2
OL,OL2
OL,OL2 (overload
advance notice signal), OD
OD
OD
OD (PID deviation error signal), AL
AL
AL
AL (alarm signal),
OTQ
OTQ
OTQ
OTQ (over/under torque threshold), UV
UV
UV
UV (under-voltage), TRQ
TRQ
TRQ
TRQ (torque limit
signal), RNT
RNT
RNT
RNT (run time expired), ONT
ONT
ONT
ONT (power ON time expired), THM
THM
THM
THM
(thermal warning), BRK
BRK
BRK
BRK (brake release), BER
BER
BER
BER (brake error), ZS
ZS
ZS
ZS (0Hz
detection), DSE
DSE
DSE
DSE (speed deviation excessive), POK
POK
POK
POK (positioning completion),
ODc
ODc
ODc
ODc (analog voltage input disconnection), OIDc
OIDc
OIDc
OIDc (analog current input
disconnection), FBV
FBV
FBV
FBV (PID second stage output), NDc
NDc
NDc
NDc (network disconnect
detection), LOG1~LOG3
LOG1~LOG3
LOG1~LOG3
LOG1~LOG3 (Logic output signals), WAC
WAC
WAC
WAC (capacitor life
warning), WAF
WAF
WAF
WAF (cooling fan warning), FR
FR
FR
FR (starting contact), OHF
OHF
OHF
OHF (heat sink
overheat warning), LOC
LOC
LOC
LOC (Low load), MO1~MO3
MO1~MO3
MO1~MO3
MO1~MO3 (general outputs for EzSQ),
IRDY
IRDY
IRDY
IRDY (inverter ready), FWR
FWR
FWR
FWR (forward operation), RVR
RVR
RVR
RVR (reverse operation),
MJA
MJA
MJA
MJA (major failure), WCO
WCO
WCO
WCO (window comparator O), WCOI
WCOI
WCOI
WCOI (window
comparator OI), FREF
FREF
FREF
FREF (frequency command source), REF
REF
REF
REF (run command
source), SETM
SETM
SETM
SETM (second motor in operation), EDM
EDM
EDM
EDM (STO (safe torque off)
performance monitor), OP
OP
OP
OP (option control signal), NO
NO
NO
NO (no function)
Monitor output (analog)
Output freq., output current, output torque, output voltage, input power,
thermal load ratio, LAD freq., heat sink temperature, general output (EzSQ)
Pulse train output
(0~10Vdc, 32kHz max.)
[PWM output]
[PWM output]
[PWM output]
[PWM output]
Output freq., output current, output torque, output voltage, input power,
thermal load ratio, LAD freq., heat sink temperature, general output (EzSQ)
[Pulse train output]
[Pulse train output]
[Pulse train output]
[Pulse train output]
Output frequency, output current, pulse train input monitor
Alarm output contact
ON for inverter alarm (1c contacts, both normally open or closed available.)
Other functions
Free-V/f, manual/automatic torque boost, output voltage gain adjustment,
AVR function, reduced voltage start, motor data selection, auto-tuning,
motor stabilization control, reverse running protection, simple position
control, simple torque control, torque limiting, automatic carrier frequency
reduction, energy saving operation, PID function, non-stop operation at
instantaneous power failure, brake control, DC injection braking, dynamic
braking (BRD), frequency upper and lower limiters, jump frequencies, curve
accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine
adjustment of start frequency, accel and decel stop, process jogging,
frequency calculation, frequency addition, 2-stage accel/decel, stop mode
selection, start/end freq., analog input filter, window comparators, input
terminal response time, output signal delay/hold function, rotation direction
restriction, stop key selection, software lock, safe stop function, scaling
function, display restriction, password function, user parameter,
initialization, initial display selection, cooling fan control, warning, trip
retry, frequency pull-in restart, frequency matching, overload restriction,
over current restriction, DC bus voltage AVR
Protective function
Over-current, over-voltage, under-voltage, overload, brake resistor overload,
CPU error, memory error, external trip, USP error, ground fault detection at
power on, temperature error, internal communication error, driver error,
thermistor error, brake error, safe stop, overload at low speed, modbus
communication error, option error, encoder disconnection, speed excessive,
EzSQ command error, EzSQ nesting error, EzSQ execution error, EzSQ user
trip
Operating
environment
Temperature
Operating (ambient): -10 to 40
°
C(*10), / Storage: -20 to 65
°
C(*11)
Humidity
20 to 90% humidity (non-condensing)
Vibration *11
5.9m/s
2
(0.6G), 10 to 55 Hz
Location
Altitude 1,000m or less, indoors (no corrosive gasses or dust)
Coating color
Black
Options
Remote operator unit, cables for the units, braking unit, braking resistor, AC
reactor, DC reactor, EMC filter, fieldbus
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......