3
60
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Initial data
Units
Initial display selection
Func. code that SET key
pressed last displayed.(*)
~
~
displayed
displayed
B display of LCD operator
001
Frequency scaling
conversion factor
Specify a constant to scale the
displayed frequency for
monitor, range is 0.01 to 99.99
1.00
Display ex.operator
connected
When an external operator is
connected via RS-422 port, the
built-in display is locked and
shows only one "d" parameter
configured in:
~
001
1st parameter of Dual
Monitor
Set any two "d" parameters in
b160 and b161, then they can be
monitored in d050. The two
parameters are switched by
up/down keys.
Set range:
~
001
2nd parameter of Dual
Monitor
002
Frequency set in monitoring Two option codes:
Freq. set disabled
Freq. set enabled
00
Automatic return to the
initial display
10 min. after the last key
operation, display returns to the
initial parameter set by
.
Two option codes:
Disable
Enable
00
Ex. operator com. loss action Five option codes:
Trip
Trip after deceleration to a
stop
Ignore
Coasting (FRS)
Decelerates to a stop
02
(*) note: If the power is off with displaying “000” after the set, b038 comes when power is on
again.
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......