Output Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
OFF
Output frequency is higher than the threshold
specified in
DSE
Speed Deviation
Excessive
ON
Deviation of speed command and actual speed
exceeds the specified value
.
OFF
Deviation of speed command and actual speed
does not exceed the specified value
.
POK
Positioning Completion
ON
Positioning is completed
OFF
Positioning is not completed
FA4
Frequency Arrival Type
4
–Over frequency
ON
When output to motor is at or above the set freq.,
even if in accel (
) or decel (
) ramps
OFF
When output to motor is OFF, or at a level below the
set frequency
FA5
Frequency Arrival Type
5
–Set frequency
ON
When output to motor is at the set frequency, during
accel (
) and decel (
).
OFF
When output to motor is OFF, or is not at a level of
the set frequency
OL2
Overload Advance
Notice Signal 2
ON
When output current is more than the set threshold
(
) for the overload signal
OFF
When output current is less than the set threshold
for the deviation signal
ODc
Analog Voltage Input
Disconnect Detection
ON
When the [O] input value <
setting (signal loss
detected)
OFF
When no signal loss is detected
OIDc
Analog Current input
Disconnect Detection
ON
When the [OI] input value <
setting (signal loss
detected)
OFF
When no signal loss is detected
FBV
PID Second Stage
Output
ON
Transitions to ON when the inverter is in RUN Mode
and the PID Process Variable (PV) is less than the
Feedback Low Limit (
)
OFF
Transitions to OFF when the PID Process Variable
(PV) exceeds the PID High Limit (
), and
transitions to OFF when the inverter goes from Run
Mode to Stop Mode
NDc
Network Disconnect
Detection
ON
When the communications watchdog timer (period
specified by
) has time out
OFF
When the communications watchdog timer is
satisfied by regular communications activity
LOG1
Logic Output Function 1 ON
When the Boolean operation specified by
has
a logical
“1” result
OFF
When the Boolean operation specified by
has
a logical
“0” result
LOG2
Logic Output Function 2 ON
When the Boolean operation specified by
has
a logical
“1” result
OFF
When the Boolean operation specified by
has
a logical
“0” result
LOG3
Logic Output Function 3 ON
When the Boolean operation specified by
has
a logical
“1” result
OFF
When the Boolean operation specified by
has
a logical
“0” result
WAC
Capacitor Life Warning
Signal
ON
Lifetime of internal capacitor has expired.
OFF
Lifetime of internal capacitor has not expired.
WAF
Cooling Fan Warning
Signal
ON
Lifetime of cooling fan has expired.
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......