5. Set the Number of Motor Poles
–
The motor’s internal winding arrangement
determines its number of magnetic poles. The specification label on the motor usually
indicates the number of poles. For proper operation, verify the parameter setting
matches the motor poles. Many industrial motors have four poles, corresponding to the
default setting in the inverter (
).
Follow the steps in the table below to verify the motor poles setting and change if
necessary (the table resumes action from the end of the previous table.)
Action
Display
Func./Parameter
(Starting point)
Level of electronic thermal setting
Press the ESC key two times
“H” Group selected
Press the
key three times
Motor poles parameter
Press the SET key.
2 = 2 poles
4 = 4 poles (default)
6 = 6 poles
8 = 8 poles
10 = 10 poles
Press the
/
key to select
Set to your motor specs (your display
may be different)
Press the SET key.
Store parameter, returns to
“
”
This step concludes the parameter setups for the inverter. You are almost ready to run
the motor for the first time!
TIP: If you became lost during any of these steps, first observe the state of the PRG
LED. Then study the “Keypad Navigation Map on page 2-26 to determine the current
state of the keypad controls and display. As long as you do not press the SET key, no
parameter will be changed by keypad entry errors. Note that power cycling the inverter
causes it to power up Monitor Mode, displaying the value for
(output frequency).
The next section will show you how to monitor a particular parameter from the display.
Then you will be ready to run the motor.
Summary of Contents for WJ200-001L
Page 2: ......
Page 3: ......
Page 49: ......
Page 299: ......
Page 300: ...5 1 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 5 ...
Page 305: ......
Page 328: ...A 1 Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A ...
Page 387: ......
Page 509: ......
Page 665: ......
Page 673: ......