E N G IN E ELECTRICAL 6Y-10
SPECIFICA TIO N S
S T A R T IN G M O T O R
M O D E L S
1107375 (a )
1107371 (a )
1107376 (a )
No Load Test—
Volts
10.6
11.8
10.6
Minim um Amps.
65*
—
*
LOLO
Maxim um Amps.
100*
72
95*
Minim um RPM
3600
6025
3800
Maxim um RPM
5100
-
6000
S T A R T IN G M O T O R
M O D E L S
1 10 7586(a)
1113659 (a )
1114101 (b )
1114121 (b )
No Load Test—
Volts
10.6
11.0
11.5
Minim um Amps.
75*
105*
90*
Maxim um Amps.
100*
155*
130*
Minim um RPM
6450
6800
5600 ■
Maxim um RPM
8750
10,400
7600
(*) Includes Solenoid.
(a) Pinion Clearances 0.010"-0.140".
(b) Pinion Clearances
± 'lh i .