ENGINE ELECTRICAL 6Y-10
can be checked for current draw, open circuit, or
shorts. Refer to "Specifications" at end of this
section for current values. Solenoid coil, terminals,
and switch plunger can be replaced if burned or
otherwise damaged. Whenever solenoid is replaced
on overrunning clutch type starting motors, pinion
clearance must be checked and adjusted, as pre
viously directed under "Pinion Clearance Check”
in this section.
STARTER MAGNETIC SWITCH
Switch is used to make and break the battery-
to-starter circuit. When control switch is turned
to " S T A R T " position, windings in magnetic switch
are energized; this causes switch contacts to close,
completing circuit from battery to starter. When
control switch is released, spring in switch causes
contacts to open. Switch requires the same main
tenance described above for "Starter Solenoid" ex
cept that there is no linkage adjustment.
SPECIFICATIONS
S T A N D A R D
PART NO.
HM/JM/TM-80 .......................................................... .1107376
HV/JV/TV-70..............................................................1114101
O P T I O N A L
HM/JM/TM-80 ........................................................ ... 1107371
HM/JM/TM-80 ........................................................ ... 1107586
S TA R TIN G MOTOR S P E C IFIC A T IO N S
STA RTER M O D E L
1107371 (a)
1107376 (a)
1107586 (a)
1114101 (b)
M ake.......................................................... Delco-Remy Delco-Remy Delco-Remy Delco-Remy
Type of D rive........................................... Overrunning Overrunning Overrunning Overrunning
Clutch
Clutch
Clutch
Clutch
Rotation (Viewing Drive E n d )...............
CW
CW
CW
CW
NO LOAD T E S T
V o lts.......................................................
11.8
10.6
10.6
11.5
Minimum A m p s...................................
—
55*
75*
90*
Maximum A m p s..................................
72
95*
100*
130*
Minimum R P M .....................................
6025
3800
6450
5600
Maximum R PM ....................................
6000
8750
7600
ST A R T ER SOLENOID
Model No...............................................
1114359
1114359
1114359
1119862
Rated Voltage.......................................
12
12
12
12
Current Consumption
Both Windings
A m ps.............................................
41-47
41-47
41-47
65.3-73.3
V o lts...............................................
10
10
10
10
Hold-ln W inding..............................
A m ps..............................................
14.5-16.5
14.5-16.5
14.5-16.5
12.7-14.3
V o lts...............................................
10
10
10
10
*
Includes Solenoid
(a ) Pinion Clearance 0.010"-0.140"
(b ) Pinion Clearance
W u 1'
plus or minus
V a "
STA R TIN G S Y S T E M TORQUE SP EC IFIC A TIO N S
ITEM
TORQ UE
(FT. LBS.)
Starter-To-Flywheel Housing Bolt
V-6 Gasoline Engine M o d e ls...............
..........
25-35
80-90
110-160
6V-53 Diesel Engine Models
TV-70 (only) ....................................................................................................................
CH EV R O Lti SERIES 70-80 H EAVY DUTY TRUCK SH O P M A N U A L
Summary of Contents for 70 1969 Series
Page 1: ...CHEVROLET HEAVY DUTY TRUCK SHOP MANUAL...
Page 3: ......
Page 11: ...LUBRICATION 0 4 CHEVROLET SERIES 70 80 HEAVY DUTY TRUCK SHOP MANUAL...
Page 27: ......
Page 119: ......
Page 361: ......
Page 371: ......
Page 427: ......
Page 443: ......
Page 451: ......
Page 493: ......
Page 499: ......
Page 549: ......
Page 555: ......
Page 609: ......
Page 715: ...am...
Page 745: ......
Page 910: ......
Page 913: ......