Appendix B: Configuration or Firmware Upgrade with a USB Drive
545
For example,
mac:7
instructs the SRC to search for the MAC
address in the 7th column of the "devices.csv" file.
The default value is
serial:1
, making the SRC search for its serial
number in the first column.
This option is used only if the "device_list" option has been set.
factory_reset
If this option is set to
true
, the SRC will be reset to factory defaults.
If the device configuration will be updated at the same time, the
factory reset will be executed before updating the device
configuration.
bulk_config_restore
Specify the name of the bulk configuration file used to configure or
restore the SRC.
Note: See
Bulk Configuration
(on page 330) for instructions on
generating a bulk configuration file.
Additional configuration keys set via the
config.txt file will be applied
after performing the bulk restore operation.
This option CANNOT be used with the option "full_config_restore."
If a firmware upgrade will be performed at the same time, you must
generate the bulk configuration file based on the NEW firmware
version instead of the current firmware version.
full_config_restore
Specify the name of the full configuration backup file used to restore
the SRC.
Note: See
Backup and Restore of Device Settings
(on page 335) for
instructions on generating the full configuration backup file.
Additional configuration keys set via the
config.txt file will be applied
after performing the configuration restore operation.
This option CANNOT be used with the option "bulk_config_restore."
If a firmware upgrade will be performed at the same time, you must
generate the full configuration backup file based on the NEW
firmware version instead of the current firmware version.
collect_diag
If this option is set to
true
, the diagnostic data of the SRC is
transmitted to the USB drive.
The filename of the diagnostic data written into the USB drive is:
diag_<unit-serial>.zip
Содержание Raritan SRC-0100
Страница 42: ...Chapter 3 Initial Installation and Configuration 30 Number Device role Master device Slave 1 Slave 2 Slave 3...
Страница 113: ...Chapter 6 Using the Web Interface 101 4 To return to the main menu and the Dashboard page click on the top left corner...
Страница 114: ...Chapter 6 Using the Web Interface 102...
Страница 128: ...Chapter 6 Using the Web Interface 116 Go to an individual sensor s or actuator s data setup page by clicking its name...
Страница 290: ...Chapter 6 Using the Web Interface 278 If wanted you can customize the subject and content of this email in this action...
Страница 291: ...Chapter 6 Using the Web Interface 279...
Страница 301: ...Chapter 6 Using the Web Interface 289 6 Click Create to finish the creation...
Страница 311: ...Chapter 6 Using the Web Interface 299...
Страница 312: ...Chapter 6 Using the Web Interface 300 Continued...
Страница 625: ...Appendix H RADIUS Configuration Illustration 613 Note If your SRC uses PAP then select PAP...
Страница 626: ...Appendix H RADIUS Configuration Illustration 614 10 Select Standard to the left of the dialog and then click Add...
Страница 627: ...Appendix H RADIUS Configuration Illustration 615 11 Select Filter Id from the list of attributes and click Add...
Страница 630: ...Appendix H RADIUS Configuration Illustration 618 14 The new attribute is added Click OK...
Страница 631: ...Appendix H RADIUS Configuration Illustration 619 15 Click Next to continue...
Страница 661: ...Appendix I Additional SRC Information 649...