18. MR-J4W2-0303B6 SERVO AMPLIFIER
18 - 44
18.5 Switch setting and display of the servo amplifier
Switching to the test operation mode, deactivating control axes, and setting control axis No. are enabled with
switches on the servo amplifier.
On the servo amplifier display (three-digit, seven-segment LED), check the status of communication with the
servo system controller at power-on, and the axis number, and diagnose a malfunction at occurrence of an
alarm.
The control axis setting switches of MR-J4W2-0303B6 servo amplifier are aligned vertically unlike other MR-
J4 2-axis servo amplifiers; however, the use of each number switch is the same.
Test operation select switch
Disabling control axis switch for A-axis
Disabling control axis switch for B-axis
For manufacturer setting
Auxiliary axis number setting switch
Auxiliary axis number setting switch
1
2
3
4
5
6
Application
ON
123456
The items in the following table are the same as those for MR-J4W2-_B and MR-J4W3-_B servo amplifiers.
Refer to the section of the detailed explanation field for details.
Item Detailed
explanation
Switches Section
4.3.1
Scrolling display
Section 4.3.2
Status display of an axis
Section 4.3.3
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...