3. SIGNALS AND WIRING
3 - 17
Device
Symbol
Function and application
AND warning
CWNG When warning has occurred, WNG turns on. When a warning is not occurring, WNG will turn off
about 3 s after power-on.
OR warning
XWNG
Warning for A-axis
WNG-A
Warning for B-axis
WNG-B
Warning for C-axis
WNG-C
AND battery warning
CBWNG BWNG turns on when [AL. 92 Battery cable disconnection warning] or [AL. 9F Battery warning] has
occurred. When the battery warning is not occurring, BWNG will turn off about 3 s after power-on.
OR battery warning
XBWNG
Battery warning for A-
axis
BWNG-A
Battery warning for B-
axis
BWNG-B
Battery warning for C-
axis
BWNG-
C
AND variable gain
selection
CCDPS CDPS will turn on during variable gain.
OR variable gain
selection
XCDPS
Variable gain
selection for A-axis
CDPS-A
Variable gain
selection for B-axis
CDPS-B
Variable gain
selection for C-axis
CDPS-C
AND absolute
position
undetermined
CABSV ABSV turns on when the absolute position is undetermined.
The device cannot be used in the speed control mode and torque control mode.
OR absolute position
undetermined
XABSV
Absolute position
undetermined for A-
axis
ABSV-A
Absolute position
undetermined for B-
axis
ABSV-B
Absolute position
undetermined for C-
axis
ABSV-C
AND during tough
drive
CMTTR When a tough drive is enabled in [Pr. PA20], activating the instantaneous power failure tough drive
will turn on MTTR.
OR during tough drive XMTTR
Tough drive for A-axis MTTR-A
Tough drive for B-axis MTTR-B
Tough drive for C-
axis
MTTR-C
AND during fully
closed loop control
CCLDS CLDS turns on during fully closed loop control.
OR during fully closed
loop control
XCLDS
During fully closed
loop control A-axis
CLDS-A
During fully closed
loop control B-axis
CLDS-B
During fully closed
loop control C-axis
CLDS-C
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...