5. PARAMETERS
5 - 10
5.1.6 Extension setting 3 parameters ([Pr. PF_ _ ])
No. Symbol
Name
Initial
value
Unit
Each/
Common
Operation
mode
Standard
F
ull.
Lin.
D.D.
PF01
For manufacturer setting
0000h
PF02
*FOP2
Function selection F-2
0000h
Common
PF03 For manufacturer setting
0000h
PF04
0
PF05
0000h
PF06
*FOP5
Function selection F-5
0000h
Each
PF07 For manufacturer setting
0000h
PF08
0000h
PF09
0
PF10
0
PF11
0
PF12
DBT
Electronic dynamic brake operating time
2000
[ms]
Each
PF13 For manufacturer setting
0000h
PF14
10
PF15
0000h
PF16
0000h
PF17
0000h
PF18 **STOD STO diagnosis error detection time
0
[s]
Common
PF19 0000h
PF20
0000h
PF21
DRT
Drive recorder switching time setting
0
[s]
Common
PF22
For manufacturer setting
200
PF23
OSCL1 Vibration tough drive - Oscillation detection level
50
[%]
Each
PF24 *OSCL2 Vibration tough drive function selection
0000h
Each
PF25
CVAT
SEMI-F47 function - Instantaneous power failure detection time
200
[ms]
Common
PF26 For manufacturer setting
0
PF27
0
PF28
0
PF29
0000h
PF30
0
PF31
FRIC
Machine diagnosis function - Friction judgment speed
0
[r/min]/
[mm/s]
Each
PF32 For manufacturer setting
50
PF33
0000h
PF34
0000h
PF35
0000h
PF36
0000h
PF37
0000h
PF38
0000h
PF39
0000h
PF40
0000h
PF41
0000h
PF42
0000h
PF43
0000h
PF44
0
PF45
0000h
PF46
0000h
PF47
0000h
PF48
0000h
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...