2. INSTALLATION
2 - 2
(1) Installation of one servo amplifier
40 mm
or more
10 mm
or more
10 mm
or more
40 mm
or more
Servo amplifier
Control box
Control box
Wiring
allowance
80 mm
Top
Bottom
(2) Installation of two or more servo amplifiers
POINT
You can install MR-J4W_-B servo amplifiers without clearances between them.
Leave a large clearance between the top of the servo amplifier and the cabinet walls, and install a cooling
fan to prevent the internal temperature of the cabinet from exceeding the environment.
When mounting the servo amplifiers closely, leave a clearance of 1 mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
100 mm
or more
10 mm
or more
30 mm
or more
30 mm
or more
40 mm
or more
Control box
Top
Bottom
100 mm
or more
1 mm
30 mm
or more
40 mm
or more
Control box
1 mm
Leaving clearance
Mounting closely