16. FULLY CLOSED LOOP SYSTEM
16 - 2
The following table shows the functions of each control mode.
Control Description
Semi closed loop control
Feature
Position is controlled according to the servo motor-side data.
Advantage
Since this control is insusceptible to machine influence (such as machine resonance),
the gains of the servo amplifier can be raised and the settling time shortened.
Disadvantage
If the servo motor side is at a stop, the side may be vibrating or the load-side accuracy
not obtained.
Dual feedback control
Feature
Position is controlled according to the servo motor-side data and load-side data.
Advantage
Control is performed according to the servo motor-side data during operation, and
according to the load side-data at a stop in sequence to raise the gains during
operation and shorten the settling time. A stop is made with the load-side accuracy.
Fully closed loop control
Feature
Position is controlled according to the load-side data.
Advantage
The load-side accuracy is obtained not only at a stop but also during operation.
Disadvantage
Since this control is susceptible to machine resonance or other influences, the gains
of the servo amplifier may not rise.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...