17. APPLICATION OF FUNCTIONS
17 - 61
2) Instantaneous power failure time of control circuit power supply < [Pr. PX28 SEMI-F47 function -
Instantaneous power failure detection time]
Operation status differs depending on how bus voltage decrease.
a) When the bus voltage decreases lower than 158 V DC within the instantaneous power failure
time of the control circuit power supply
[AL. 10 Undervoltage] occurs when the bus voltage decrease lower than 158 V DC regardless
of the enabled instantaneous power failure tough drive.
[Pr. PX28]
Instantaneous power failure time of the control circuit power supply
ON
OFF
ON (energization)
OFF (power failure)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Control circuit
power supply
Bus voltage
Undervoltage level
(158 V DC)
CALM
(AND malfunction)
MTTR
(During tough drive)
MBR
(Electromagnetic
brake interlock)
Base circuit
WNG
(Warning)