8. TROUBLESHOOTING
8 - 16
Display Description
Cause
Checkpoint
Action
Ab
AC
or
Ab
AC
Ad
Communication between
servo system controller
and servo amplifier are
repeating connection and
shut-off.
An MR-J4-_B(4)(-RJ)
servo amplifier or MR-
J4W_-_B servo amplifier
which is set to J3
compatibility mode is
connected to the
SSCNET III/H network.
Check if "J3 compatibility mode"
is set using "MR-J4(W)-B mode
selection" which came with MR
Configurator2.
Select "J4 mode" with "MR-
J4(W)-B mode selection".
b##.
(Note)
The system has been in
the test operation mode.
Test operation mode has
been active.
Test operation setting switch
(SW2-1) is turned on.
Turn off the test operation setting
switch (SW2-1).
off
Operation mode for
manufacturer setting is
set.
Operation mode for
manufacturer setting is
enabled.
Check if all of the control axis
setting switches (SW2) are on.
Set the control axis setting
switches (SW2) correctly.