11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 30
(b) For MR-J4W3
Total output of
rotary servo
motors
Total
continuous
thrust of linear
servo motors
Total output of
direct drive
motors
Molded-case circuit breaker
(Note 4, 5)
Fuse
(Note 2)
Magnetic
contactor
Frame, rated current
Voltage
AC
[V]
(Note 1)
Class
Current
[A]
Voltage
AC
[V]
450 W or less
150 N or less
50 A frame 10 A
(Note 3)
240 T
20
300
S-N10
S-T10
From over 450
W to 800 W
From over 150
N to 300 N
252 W or less
50 A frame 15 A
(Note 3)
20
From over 800
W to 1.5 kW
From over 300
N to 450 N
From over 252
W to 378 W
50 A frame 20 A
(Note 3)
30
S-N20
S-T21
Note 1. When using the servo amplifier as an EC/EN/UL/CSA standard compliant product, refer to app. 4.
2. Use a magnetic contactor with an operation delay time (interval between current being applied to the coil until
closure of contacts) of 80 ms or less.
3. When not using the servo amplifier as an EC/EN/UL/CSA standard compliant product, molded-case circuit breaker
of 30 A frame can be used.
4.
A molded-case circuit breaker will not change to select regardless of use of a power factor improving AC reactor.
5. Use a molded-case circuit breaker having the operation characteristics equal to or higher than Mitsubishi Electric
general-purpose products.
The Type E Combination motor controller can also be used instead of a molded-case circuit breaker.
Servo amplifier
Rated input
voltage AC [V]
Input phase
Type E Combination motor controller
SCCR
[kA]
Model
Rated voltage
AC [V]
Rated current [A]
(Heater design)
MR-J4W2-22B 6.3
MR-J4W2-44B 8
MR-J4W2-77B
200 to 240
3-phase
MMP-T32
240
13
50
MR-J4W2-1010B
18
MR-J4W3-222B 8
MR-J4W3-444B 13
(2) For control circuit power supply
When the wiring for the control circuit power supply (L11/L21) is thinner than that for the main circuit
power supply (L1/L2/L3), install an overcurrent protection device (molded-case circuit breaker or fuse) to
protect the branch circuit.
Servo amplifier
Molded-case circuit breaker
Fuse (Class T)
Fuse (Class K5)
Frame, rated current
Voltage AC
[V]
Current [A]
Voltage AC
[V]
Current [A]
Voltage AC
[V]
MR-J4W2-22B
MR-J4W2-44B
MR-J4W2-77B
50 A frame 5 A (Note)
240
1
300
1
250
MR-J4W2-1010B
MR-J4W3-222B
MR-J4W3-444B
Note. When not using the servo amplifier as an EC/EN/UL/CSA standard compliant product, molded-case circuit breaker of
30 A frame can be used.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...