4. STARTUP
4 - 15
4.5.1 Test operation mode in MR Configurator2
POINT
All axes will be in the test operation mode for the multi-axis servo amplifier.
Although only one axis is active in the mode.
When the test operation mode is selected with the test operation select switch
(SW2-1), the SSCNET III/H communication for the servo amplifier in the test
operation mode and the following servo amplifiers is blocked.
(1) Test operation mode
(a) Jog operation
Jog operation can be performed without using the servo system controller. Use this operation with
the forced stop reset. This operation may be used independently of whether the servo is on or off
and whether the servo system controller is connected or not.
Exercise control on the jog operation screen of MR Configurator2.
1) Operation pattern
Item
Default value
Setting range
Speed [r/min]
200
0 to max. speed
Acceleration/deceleration
time constant [ms]
1000
0 to 50000
2) Operation method
When the check box of "Rotation only while the CCW or CW button is being pushed." is
checked.
Operation Screen
control
Forward rotation start
Keep pressing "Forward".
Reverse rotation start
Keep pressing "Reverse".
Stop
Release "Forward" or "Reverse".
Forced stop
Click "Forced stop".
When the check box of "Rotation only while the CCW or CW button is being pushed." is not
checked.
Operation Screen
control
Forward rotation start
Click "Forward".
Reverse rotation start
Click "Reverse".
Stop Click
"Stop".
Forced stop
Click "Forced stop".
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...