APPENDIX
App. - 50
App. 12.2.3 Specifications
(1) Special coating
Using the MR-J4 series in an atmosphere containing a corrosive gas may cause its corrosion with time,
resulting in a malfunction. For the printed circuit board of the servo amplifiers with a special coating
specification, a urethane coating agent is applied to some parts capable of being coated technically
(except LEDs, connectors, terminal blocks, etc.) to improve the resistance to corrosive gases. Use a
servo amplifier with a special coating specification specifically for applications susceptible to corrosive
gases, including tire manufacturing and water treatment. Although the special coating-specification
products have the improved resistance to corrosive gases, proper operations in environments
mentioned above are not guaranteed. Therefore, perform periodic inspections for any abnormality.
(2) Standard for corrosive gases
In IEC 60721-3-3, corrosive gases refer to sea salt, sulfur dioxide, hydrogen sulfide, chlorine, hydrogen
chloride, hydrogen fluoride, ammonia, ozone, and nitrogen oxides shown in the environmental
parameter column of the table below.
The table also shows the corrosive gas concentrations defined in IEC 60721-3-3, Class 3C2.
Environmental parameter
Unit
3C2
Mean value
Maximum value
a) Sea salt
None
Salt mist
b) Sulfur dioxide
cm
3
/m
3
0.11 0.37
c) Hydrogen sulfide
cm
3
/m
3
0.071 0.36
d) Chlorine
cm
3
/m
3
0.034 0.1
e) Hydrogen chloride
cm
3
/m
3
0.066 0.33
f) Hydrogen fluoride
cm
3
/m
3
0.012 0.036
g) Ammonia
cm
3
/m
3
1.4 4.2
h) Ozone
cm
3
/m
3
0.025 0.05
i) Nitrogen oxides
cm
3
/m
3
0.26 0.52
The special coating-specification products have the improved corrosion resistance in environments with
corrosive gas concentrations conforming to IEC 60721-3-3, Class 3C2. We tested typical models and
confirmed that their corrosive gas resistance was improved, compared with the standard models.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...