18. MR-J4W2-0303B6 SERVO AMPLIFIER
18 - 12
(2) Installation of two or more servo amplifiers
POINT
You can install MR-J4W2-0303B6 servo amplifiers without clearances between
them. When closely mounting the servo amplifiers, operate them at the ambient
temperatures of 45
˚
C or lower, or the total effective load ratio of 45 w or lower
for the two axes.
Leave a large clearance between the top of the servo amplifier and the cabinet walls, and install a cooling
fan to prevent the internal temperature of the cabinet from exceeding the environmental conditions.
When mounting the servo amplifiers closely, leave a clearance of 1 mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
100 mm
or more
5 mm
or more
30 mm
or more
30 mm
or more
40 mm or more
Cabinet
Top
Bottom
100 mm or more
1 mm
30 mm
or more
40 mm or more
Cabinet
1 mm
Leaving clearance
Mounting closely