5. PARAMETERS
5 - 33
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
Each/
Common
PB45 CNHF
Table 5.6 Notch depth selection
Refer to Name
and function
column.
Each
Setting value
Depth [dB]
Setting value
Depth [dB]
_ 0 _ _
-40.0
_ 8 _ _
-6.0
_ 1 _ _
-24.1
_ 9 _ _
-5.0
_ 2 _ _
-18.1
_ A _ _
-4.1
_ 3 _ _
-14.5
_ B _ _
-3.3
_ 4 _ _
-12.0
_ C _ _
-2.5
_ 5 _ _
-10.1
_ D _ _
-1.8
_ 6 _ _
-8.5
_ E _ _
-1.2
_ 7 _ _
-7.2
_ F _ _
-0.6
PB46
NH3
Machine resonance suppression filter 3
Set the notch frequency of the machine resonance suppression filter 3.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 3 selection" in [Pr. PB47].
4500
[Hz]
10 to
4500
Each
PB47
NHQ3
Notch shape selection 3
Set the shape of the machine resonance suppression filter 3.
Refer to Name
and function
column.
Each
Setting
digit
Explanation
Initial
value
_ _ _ x
Machine resonance suppression filter 3 selection
0: Disabled
1: Enabled
0h
_ _ x _
Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _
Notch width selection
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
0h
x _ _ _
For manufacturer setting
0h
PB48
NH4
Machine resonance suppression filter 4
Set the notch frequency of the machine resonance suppression filter 4.
To enable the setting value, select "Enabled (_ _ _ 1)" of "Machine resonance
suppression filter 4 selection" in [Pr. PB49].
4500
[Hz]
10 to
4500
Each
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...