7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 18
(2) Switchable gain parameter
Loop gain
Before switching
After switching
Parameter Symbol
Name
Parameter Symbol
Name
Load to motor inertia
ratio/load to motor mass
ratio
PB06
GD2
Load to motor inertia
ratio/load to motor mass
ratio
PB29
GD2B
Load to motor inertia
ratio/load to motor mass
ratio after gain switching
Model loop gain
PB07
PG1
Model loop gain
PB60
PG1B
Model loop gain after gain
switching
Position loop gain
PB08
PG2
Position loop gain
PB30
PG2B
Position loop gain after
gain switching
Speed loop gain
PB09
VG2
Speed loop gain
PB31
VG2B
Speed loop gain after gain
switching
Speed integral
compensation
PB10 VIC
Speed
integral
compensation
PB32 VICB
Speed
integral
compensation after gain
switching
Vibration suppression
control 1 - Vibration
frequency
PB19 VRF11
Vibration
suppression
control 1 - Vibration
frequency
PB33 VRF11B
Vibration
suppression
control 1 - Vibration
frequency after gain
switching
Vibration suppression
control 1 - Resonance
frequency
PB20 VRF12
Vibration
suppression
control 1 - Resonance
frequency
PB34 VRF12B
Vibration
suppression
control 1 - Resonance
frequency after gain
switching
Vibration suppression
control 1 - Vibration
frequency damping
PB21 VRF13
Vibration
suppression
control 1 - Vibration
frequency damping
PB35 VRF13B
Vibration
suppression
control 1 - Vibration
frequency damping after
gain switching
Vibration suppression
control 1 - Resonance
frequency damping
PB22 VRF14
Vibration
suppression
control 1 - Resonance
frequency damping
PB36 VRF14B
Vibration
suppression
control 1 - Resonance
frequency damping after
gain switching
Vibration suppression
control 2 - Vibration
frequency
PB52 VRF21
Vibration
suppression
control 2 - Vibration
frequency
PB56 VRF21B
Vibration
suppression
control 2 - Vibration
frequency after gain
switching
Vibration suppression
control 2 - Resonance
frequency
PB53 VRF22
Vibration
suppression
control 2 - Resonance
frequency
PB57 VRF22B
Vibration
suppression
control 2 - Resonance
frequency after gain
switching
Vibration suppression
control 2 - Vibration
frequency damping
PB54 VRF23
Vibration
suppression
control 2 - Vibration
frequency damping
PB58 VRF23B
Vibration
suppression
control 2 - Vibration
frequency damping after
gain switching
Vibration suppression
control 2 - Resonance
frequency damping
PB55 VRF24
Vibration
suppression
control 2 - Resonance
frequency damping
PB59 VRF24B
Vibration
suppression
control 2 - Resonance
frequency damping after
gain switching
(a) [Pr. PB06] to [Pr. PB10]
These parameters are the same as in ordinary manual adjustment. Gain switching allows the values
of load to motor inertia ratio/load to motor mass ratio, position loop gain, model loop gain, speed loop
gain, and speed integral compensation to be switched.
(b) [Pr. PB19] to [Pr. PB22]/[Pr. PB52] to [Pr. PB55]
These parameters are the same as in ordinary manual adjustment. Executing gain switching while
the servo motor stops, You can change vibration frequency, resonance frequency, vibration
frequency damping, and resonance frequency damping.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...