15. USING A DIRECT DRIVE MOTOR
15 - 9
(b) Magnetic pole detection by the minute position detection method
Is the moving distance
during the magnetic pole
detection acceptable?
(Note 3)
Turn the servo amplifier power off and on again.
Execute "Forward rotation CCW" or "Reverse rotation CW" with "Positioning operation" in the test
operation mode on MR Configurator2. Set the moving distance to "0" at this time.
Set [Pr. PL08 Linear servo motor/DD motor function selection 3] to "_ _ _ 4" to set the magnetic pole
detection method to "Minute position detection method".
The magnetic pole detection is carried out.
Is the response of the
minute position detection method
of [Pr. PL17] the final value?
Has an abnormal sound or
vibration occurred during the
magnetic pole detection?
Decrease the response of the minute
position detection method of [Pr. PL17] by
two as the final setting value.
Increase the response of the minute
position detection method of [Pr. PL17] by
one.
Not
acceptable
YES
Acceptable
NO
YES
NO
Magnetic pole detection
End
Set [Pr. PL01] to "_ _ _ 0" to set "Magnetic pole detection disabled". (Note)
Check that FLS (Upper stroke limit), RLS (Lower stroke limit), and EM2 (Forced stop 2) are on, and
turn the servo amplifier power off and on again.
Turn "On (up)" the test operation select switch (SW2-1) of the servo amplifier, and then cycle the
power of the servo amplifier.
Set [Pr. PL01 Linear servo motor/DD motor function selection 1] to "_ _ _ 1" to set "Magnetic pole
detection always enabled". (Note 1)
Set the load inertia moment ratio of the direct drive motor with [Pr. PL17 Magnetic pole detection -
Minute position detection method - Function selection]. (Note 2)
1)
2)
3)
4)
5)
6)
7)
8)
Note 1. For the incremental system, the [Pr. PL01] setting is not required.
2. If the load to direct drive motor inertia ratio is unknown, perform the magnetic pole detection by the
position detection method, and then perform the auto tuning to set an estimated value.
3. For the magnetic pole detection by the minute position detection method, the maximum rotation angle
at the magnetic pole detection must be five degrees or less. To shorten the travel distance, increase
the response by the minute position detection method in [Pr. PL17].
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...