10. CHARACTERISTICS
10 - 8
10.3.2 Permissible load to motor inertia when the dynamic brake is used
Use the dynamic brake under the load to motor inertia ratio indicated in the following table. If the load inertia
moment is higher than this value, the dynamic brake may burn. If there is a possibility that the load inertia
moment may exceed the value, contact your local sales office.
The values of the permissible load to motor inertia ratio in the table are the values at the maximum rotation
speed of the servo motor.
Servo motor
Permissible load to motor inertia
ratio [multiplier]
Servo
motor
Permissible load to motor inertia
ratio [multiplier]
HG-KR053
HG-SR51
30
HG-KR13
HG-SR81
HG-KR23 30
HG-SR52
HG-KR43
HG-SR102
HG-KR73
HG-UR72
HG-MR053 35
HG-JR53
HG-MR13
HG-JR73
HG-MR23
32
HG-JR103
HG-MR43
HG-MR73