4. STARTUP
4 - 3
4.1.2 Wiring check
(1) Power supply system wiring
Before switching on the main circuit and control circuit power supplies, check the following items.
(a) Power supply system wiring
The power supplied to the power input terminals (L1/L2/L3/L11/L21) of the servo amplifier should
satisfy the defined specifications. (Refer to section 1.3.)
(b) Connection of servo amplifier and servo motor
1) The CNP3A, CNP3B, or CNP3C connector should be connected to each A-axis, B-axis, or C-axis
servo motor. The servo amplifier power output (U/V/W) should match in phase with the servo
motor power input terminals (U/V/W).
Servo amplifier
A-axis servo motor
U
V
W
M
U
V
W
CNP3A
B-axis servo motor
U
V
W
M
U
V
W
CNP3B
C-axis servo motor
U
V
W
M
U
V
W
CNP3C
2) The power supplied to the servo amplifier should not be connected to the power outputs (U/V/W).
Otherwise, the servo amplifier and servo motor will fail.
Servo amplifier
Servo motor
M
U
V
W
U
V
W
L1
L2
L3
3) The grounding terminal of the servo motor should be connected to the PE terminal of the CNP3_
connector of the servo amplifier.
Servo amplifier
Servo motor
M
4) The CN2A, CN2B, or CN2C connector should be connected using encoder cables securely to
each A-axis, B-axis, or C-axis encoder of the servo motors.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...