5. PARAMETERS
5 - 5
No. Symbol
Name
Initial
value
Unit
Each/
Common
Operation
mode
Standard
F
ull.
Lin.
D.D.
PB43 For manufacturer setting
0000h
PB44
0.00
PB45
CNHF
Command notch filter
0000h
Each
PB46
NH3
Machine resonance suppression filter 3
4500
[Hz]
Each
PB47
NHQ3
Notch shape selection 3
0000h
Each
PB48
NH4
Machine resonance suppression filter 4
4500
[Hz]
Each
PB49
NHQ4
Notch shape selection 4
0000h
Each
PB50
NH5
Machine resonance suppression filter 5
4500
[Hz]
Each
PB51
NHQ5
Notch shape selection 5
0000h
Each
PB52
VRF21 Vibration suppression control 2 - Vibration frequency
100.0
[Hz]
Each
PB53
VRF22 Vibration suppression control 2 - Resonance frequency
100.0
[Hz]
Each
PB54
VRF23 Vibration suppression control 2 - Vibration frequency damping
0.00
Each
PB55
VRF24 Vibration suppression control 2 - Resonance frequency damping
0.00
Each
PB56 VRF21B Vibration suppression control 2 - Vibration frequency after gain
switching
0.0 [Hz]
Each
PB57 VRF22B Vibration suppression control 2 - Resonance frequency after gain
switching
0.0 [Hz]
Each
PB58 VRF23B Vibration suppression control 2 - Vibration frequency damping
after gain switching
0.00 Each
PB59 VRF24B Vibration
suppression
control 2 - Resonance frequency damping
after gain switching
0.00 Each
PB60
PG1B
Model loop gain after gain switching
0.0
[rad/s]
Each
PB61 For manufacturer setting
0.0
PB62
0000h
PB63
0000h
PB64
0000h
5.1.3 Extension setting parameters ([Pr. PC_ _ ])
No. Symbol
Name
Initial
value
Unit
Each/
Common
Operation
mode
Standard
F
ull.
Lin.
D.D.
PC01
ERZ
Error excessive alarm level
0
[rev]/
[mm]
Each
PC02
MBR
Electromagnetic brake sequence output
0
[ms]
Each
PC03
*ENRS Encoder output pulse selection
0000h
Each
PC04 **COP1 Function selection C-1
0000h
Each
PC05 **COP2 Function selection C-2
0000h
Each
PC06
*COP3 Function selection C-3
0000h
Each
PC07 ZSP Zero
speed
50
[r/min]/
[mm/s]
Each
PC08
OSL
Overspeed alarm detection level
0
[r/min]/
[mm/s]
Each
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...