4. STARTUP
4 - 17
(2) Operation procedure
1) Turn off the power.
2) Turn "ON (up)" SW2-1.
1
ON
2 3 4 5 6
1 2 3 4 5 6
ON
Set SW2-1 to "ON (up)".
Turning "ON (up)" SW2-1 during power-on will not start the test operation mode.
3) Turn on the servo amplifier.
When initialization is completed, the decimal point on the first digit will blink.
Example: MR-J4 2-axis servo amplifier
After 1.6 s
After 0.2 s
After 1.6 s
After 0.2 s
Blinking
Blinking
When an alarm or warning also occurs during the test operation, the decimal point will blink.
After 0.8 s
After 0.8 s
After 0.2 s
Blinking
Blinking
4) Start operation with the personal computer.
4.5.2 Motor-less operation in controller
POINT
Use motor-less operation which is available by making the servo system
controller parameter setting.
Connect the servo amplifier with the servo system controller before the motor-
less operation.
The motor-less operation is not used in the fully closed loop control mode, linear
servo motor control mode, and DD motor control mode.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...