3. SIGNALS AND WIRING
3 - 38
3.11 Grounding
WARNING
Ground the servo amplifier and servo motor securely.
To prevent an electric shock, always connect the protective earth (PE) terminal
(marked ) of the servo amplifier to the protective earth (PE) of the cabinet.
The servo amplifier switches the power transistor on-off to supply power to the servo motor. Depending on
the wiring and ground cable routing, the servo amplifier may be affected by the switching noise (due to di/dt
and dv/dt) of the transistor. To prevent such a fault, refer to the following diagram and always ground.
To conform to the EMC Directive, refer to "EMC Installation Guidelines".
(Note 1)
Power
supply
Cabinet
Servo amplifier
Protective earth (PE)
Outer box
L1
L2
L3
CNP1
L11
L21
CNP2
MC
MCCB
W
V
U
A-axis servo motor
M
U
W
CN2A
CNP3A
Encoder
(Note 3)
V
W
V
U
B-axis servo motor
M
U
W
CN2B
CNP3B
Encoder
(Note 3)
V
W
V
U
C-axis servo motor
(Note 2)
M
U
W
CN2C
CNP3C
Encoder
(Note 3)
V
Line filter
Ser
vo system
controller
Note 1. For power supply specifications, refer to section 1.3.
2. For the MR-J4 3-axis servo amplifier
3. Be sure to connect it to of CNP3A, CNP3B, and CNP3C. Do not connect the wire directly to
the protective earth of the cabinet.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...