11. OPTIONS AND PERIPHERAL EQUIPMENT
11 - 45
11.12 Junction terminal block MR-TB26A
(1) Usage
Always use the junction terminal block (MR-TB26A) with the option cable (MR-TBNATBL_M) as a set.
To use a junction terminal block, mount it to the DIN rail.
Cable length
05: 0.5 m
1: 1 m
M R
B
B
A
T
T
L
N
M
5
-
0
Terminal numbers on a junction terminal block correspond with the pin numbers on the CN3 connector
of a servo amplifier. The terminal symbol S is for the shield.
Junction terminal block
MR-TB26A
Junction terminal block cable
(MR-TBNATBL_M)
CN3
Servo amplifier
Ground the junction terminal block cable using the S terminal of the junction terminal block.
(2) Specifications
Junction terminal block
Item
MR-TB26A
Rating
32 V AC/DC 0.5 A
Stranded wire
0.08 mm
2
to 1.5 mm
2
(AWG 28 to 14)
Usable cables
Solid wire
φ
0.32 mm to 1.2 mm
Wire insulator OD
φ
3.4 mm or less
Tool
210-619 (WAGO) or equivalent
210-119SB (WAGO) or equivalent
Stripped length
5 mm to 6 mm