3. SIGNALS AND WIRING
3 - 35
(e) Main circuit power supply off during control circuit power supply on
When the main circuit power supply is turned off, all axes will be the operation status below.
POINT
In the torque control mode, the forced stop deceleration function is not available.
CALM (AND malfunction)
MBR
(Electromagnetic
brake interlock)
ON
OFF
ON
OFF
ON (no alarm)
OFF (alarm)
(Note 2)
The time until a voltage
drop is detected.
Main circuit power supply
ON
OFF
Dynamic brake
Forced stop deceleration
Dynamic brake
+ Electromagnetic brake
Electromagnetic brake
Operation delay time of
the electromagnetic brake
Servo motor speed
0 r/min
Approx. 10 ms
(Note 1)
Base circuit
(Energy supply to
the servo motor)
Note 1. ON : Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
2. Variable according to the operation status.
(f) Ready-off command from controller
When ready-off is received, all axes will be the operation status below.
Electromagnetic brake
MBR
(Electromagnetic
brake interlock)
Base circuit
Servo motor speed
Ready-on command
(from controller)
(Note)
ON
OFF
ON
OFF
ON
OFF
Approx. 10 ms
0 r/min
Dynamic brake
Dynamic brake
+ Electromagnetic brake
Operation delay time of
the electromagnetic brake
Note. ON : Electromagnetic brake is not activated.
OFF: Electromagnetic brake is activated.
Summary of Contents for MR-J4W2-0303B6
Page 39: ...2 INSTALLATION 2 8 MEMO ...
Page 97: ...4 STARTUP 4 20 MEMO ...
Page 181: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 235: ...9 DIMENSIONS 9 6 MEMO ...
Page 245: ...10 CHARACTERISTICS 10 10 MEMO ...
Page 309: ...13 USING STO FUNCTION 13 14 MEMO ...
Page 365: ...15 USING A DIRECT DRIVE MOTOR 15 24 MEMO ...
Page 389: ...16 FULLY CLOSED LOOP SYSTEM 16 24 MEMO ...
Page 461: ...17 APPLICATION OF FUNCTIONS 17 72 MEMO ...
Page 556: ...APPENDIX App 41 ...
Page 585: ...MEMO ...