DEF SCR SYSTEM (DCU)
5–220
INSPECTION PROCEDURE: P20A3
1.
Check the connection of the DEF pump connector (Looseness and
poor contact).
NO
YES
1.
Set the starter switch to the "LOCK" position.
2.
Disconnect the DEF pump connector.
3.
Use the electrical tester to measure the resistance between the
terminals of the DEF pump (reverting valve).
NO
YES
1
Inspect the DEF pump (reverting valve) connector
Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 2.
2
Inspect the DEF pump (reverting valve) unit
PMV+
PMV-
SAPH16F020400145
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
DEF pump
(Reverting valve)
connector
PMV+
–
PMV-
23
C {73.4
F}:
2.05
–
12.05
Do the measurements meet the standard value?
Go to step 3.
Replace the DEF pump.
Perform "After-inspection work" of INFOR-
MATION section.