ENGINE CONTROL SYSTEM (J08E)
4–1175
1.
In the obtained log, check if [FAILED_IGNITION (MISFIRE)],
[LOST_FLAME], [CANNOT_ ACHIEVE_TEMP] are present after
[EECU_REQUEST_START_MANUAL_REGEN].
HINT
If there is a FAILED_IGNITION (MISFIRE), LOST_FLAME,
CANNOT_REACH_TEMP, regeneration has not been performed
because of a burner defect, although the DPR manual regenera-
tion request has been received correctly by the BCU.
NO
YES
1.
Inspect the DPR switch connector (mating, poor contact).
2.
Inspect the switch unit.
3.
Inspect the harness for disconnections and short-circuits.
7
Check burner system 4 [Hino-DX]
No
Event #
TR hours
Event
Flame temp
857
1228:24:36 EECU_REQUEST_START_MANUAL_REGEN
202
858
1228:24:58
IGNITION_SUCCESS
196
859
1228:25:17 EECU_REQUEST_STOP_REGEN
496
Yes
Event #
TR hours
Event
Flame temp
574
1866:23:18 EECU_REQUEST_START_MANUAL_REGEN
244
575
1866:23:48
FAILED_IGNITION (MISFIRE)
213
Yes
Event #
TR hours
Event
Flame temp
934
1254:47:38 EECU_REQUEST_START_MANUAL_REGEN
246
935
1254:47:59
IGNITION_SUCCESS
223
936
1254:50:01
CANNOT_REACH_TEMP
132
937
1254:50:01 EECU_REQUEST_STOP_REGEN
132
Yes
Event #
TR hours
Event
Flame temp
948
1258:33:04 EECU_REQUEST_START_MANUAL_REGEN
266
949
1258:33:26
IGNITION_SUCCESS
232
950
1258:33:49
LOST_FLAME
197
Event log example
SAPH16F010300917
Did you find a response log
?
If [FAILED IGNITION (MISFIRE)] is displayed,
go to DTC P140D inspection procedure.
If [LOST FLAME] is displayed, go to DTC
P140E inspection procedure.
If [CANNOT ACHIEVE TEMP] is displayed, go
to DTC P1400 inspection procedure.
This is due to the fact that during the DPR
manual regeneration stepping on the accel-
erator pedal, moving the shift, working on
the PTO and pressing two time the DPR but-
ton will cancel the manual regeneration.
•
Replace the DPR filter and the burner
nozzle, and clean the igniter.
After performing the DPR manual regenera-
tion, the inspection procedure will be com-
plete.
Perform "After-inspection work" of INFOR-
MATION section.
8
Inspect DPR manual regeneration switch (DPR switch)
SAPH16F010300918
Was any failure found?
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...