DEF SCR SYSTEM (DCU)
5–34
INSPECTION PROCEDURE: P0072
1.
Check the connection of the ambient air temperature sensor con-
nector (Looseness and poor contact).
NO
YES
1.
Check the connection of the external resistor connector (Loose-
ness and poor contact).
NO
YES
1.
Check the installation of the ambient air temperature sensor.
2.
Make sure there is no dirt or damage to the sensing unit of the
ambient air temperature sensor.
1
Inspect the ambient air temperature sensor connector
Ambient sensor
DEF tank
SAPH16F020400024
Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 2.
2
Inspect the connector of the external resistor
Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 3.
3
Inspect the ambient air temperature sensor
Was any failure found?
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...