DEF SCR SYSTEM (DCU)
5–27
CHECKLIST: P0071
DTC: P0071
Ambient air temperature sensor - rationality
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No
1
Inspect the
ambient air
temperature
sensor con-
nector
Check the connection of the
ambient air temperature sensor
connector (Looseness and poor
contact).
Failure found:
Go to YES.
No failure
found: Go to
NO.
Connect
securely,
repair if
needed.
Perform "After-
inspection
work" of
INFORMA-
TION section.
Go to step 2.
2
Inspect the
connector of
the external
resistor
Check the connection of the
external resistor connector
(Looseness and poor contact).
Failure found:
Go to YES.
No failure
found: Go to
NO.
Connect
securely,
repair if
needed.
Perform "After-
inspection
work" of
INFORMA-
TION section.
Go to step 3.
3
Inspect the
DCU 86P con-
nector
Check the connection of the DCU
86P connector (Looseness and
poor contact).
Failure found:
Go to YES.
No failure
found: Go to
NO.
Connect
securely,
repair if
needed.
Perform "After-
inspection
work" of
INFORMA-
TION section.
Go to step 4.
4
Inspect the
ambient air
temperature
sensor
1.
Check the installation of the
ambient air temperature
sensor.
2.
Make sure there is no dirt or
damage to the ambient air
temperature sensor.
Failure found:
Go to YES.
No failure
found: Go to
NO.
Clean the
ambient air
temperature
sensor and
install it prop-
erly.
If damaged,
replace the
ambient air
temperature
sensor.
Perform "After-
inspection
work" of
INFORMA-
TION section.
Go to step 5.
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...