DEF SCR SYSTEM (DCU)
5–270
1.
Set the starter switch to the "LOCK" position.
2.
Disconnect the SST2 DEF tank side connector (1) and fill a clean
small container with clean DEF.
3.
Set the starter switch to the "ON" position.
4.
Perform the [Leak test] as same as step 2.
HINT
•
The DEF is discharged from the connector in the container.
NO
YES
4
Inspect the DEF pressure 2 (Inspection of the DEF sensor) [Hino-DX]
(2)
(1)
DEF
sensor
Separate
container
SAPH16F020400184
Measurement
condition
Standard values
Starter switch: ON
The DEF pressure is stable in the 8,500
to 9,500 hPa (123.3 to 137.8 psi) range
for 60 seconds.
Do the measurements meet the standard value?
Replace the DEF sensor.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 5.