DEF SCR SYSTEM (DCU)
5–148
INSPECTION PROCEDURE: P204C
1.
Check the connection of the DEF pump connector (Looseness and
poor contact).
NO
YES
1.
Set the starter switch to the "LOCK" position.
2.
Remove the DEF pump connector.
3.
Use the electrical tester to measure the resistance between the
terminals of the DEF pump pressure sensor.
NO
YES
1
Inspect the DEF pump connector
Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 2.
2
Inspect the DEF pump (pressure sensor) unit
PSR+
PSRS
PSR-
SAPH16F020400096
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
DEF pump
connector
(1) PSR+
–
PSR-
(2) PSR+
–
PSRS
(3) PSR-
–
PSRS
(1) 185
–
215 k
(2) 148
–
172 k
(3) 333
–
387 k
Do the measurements meet the standard value?
Go to step 3.
Replace the DEF pump.
Perform "After-inspection work" of INFOR-
MATION section.
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...