DEF SCR SYSTEM (DCU)
5–163
NO
YES
1.
Set the starter switch to the "LOCK" position.
2.
Disconnect the ambient air temperature sensor connector.
3.
Use the electrical tester to measure the resistance between the
terminals of the ambient air temperature sensor.
NO
YES
1.
Check the connection of the DCU 86P connector (Looseness and
poor contact).
NO
YES
Clean the ambient air temperature sensor
and install it properly. If damaged, replace
the ambient air temperature sensor.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 4.
4
Inspect the ambient air temperature sensor unit
HH1+
LJK
HH1-
LGK
HH1-
HH1+
SAPH16F020400107
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
Ambient air tem-
perature sensor
HH1+
–
HH1-
1.7 k
Do the measurements meet the standard value?
Go to step 5.
Replace the ambient air temperature sensor.
Perform "After-inspection work" of INFOR-
MATION section.
5
Inspect the DCU 86P connector
Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 6.