DEF SCR SYSTEM (DCU)
5–221
1.
Disconnect the DCU 86P connector.
2.
Connect the signal check harness and use the electrical tester to
measure the resistance between the terminals of the DCU 86P
vehicle-side connector and the ground.
NO
YES
1.
Connect the DEF pump connector.
2.
Connect the signal check harness and use the electrical tester to
measure the resistance between the terminals of the DCU 86P
vehicle-side connector.
3
Inspect for short-circuit in the DEF pump (reverting valve) harness
PMV+
PMV-
SAPH16F020400146
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
DCU 86P vehicle-
side connector
PMV+
–
Ground
PMV-
–
Ground
Do the measurements meet the standard value?
Go to step 4.
Repair or replace the harness.
Perform "After-inspection work" of INFOR-
MATION section.
4
Inspect disconnection of the DEF pump (reverting valve) harness
PMV+
PMV-
SAPH16F020400147
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...