DEF SCR SYSTEM (DCU)
5–203
INSPECTION PROCEDURE: P20A0
1.
Check the connection of the DEF pump (reverting valve) connector
(Looseness and poor contact).
NO
YES
1.
Set the starter switch to the "LOCK" position.
2.
Disconnect the DEF pump connector.
3.
Use the electrical tester to measure the resistance between the
terminals of the DEF pump (reverting valve).
NO
YES
1
Inspect the DEF pump (reverting valve) connector
Was any failure found?
Connect securely, repair if needed.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 2.
2
Inspect the DEF pump (reverting valve) unit
PMV+
PMV-
SAPH16F020400131
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
DEF pump
(reverting valve)
connector
PMV+
–
PMV-
23
C {73.4
F}:
2.05
–
12.05
Do the measurements meet the standard value?
Go to step 3.
Replace the DEF pump.
Perform "After-inspection work" of INFOR-
MATION section.
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...