DEF SCR SYSTEM (DCU)
5–50
5
Inspect the
external resis-
tor unit
Measure the resistance between
the terminals of the external resis-
tor.
<Tester connections>
External resistor
ER+
–
ER-
<Standard values>
2 k
The measure-
ments meet
the standard
value: Go to
YES.
The measure-
ments do not
meet the stan-
dard value: Go
to NO.
Go to step 6.
Replace the
external resis-
tor
Perform "After-
inspection
work" of
INFORMA-
TION section.
6
Inspect the
sensor power
supply
Measure the voltage between the
terminals of the ambient air tem-
perature sensor vehicle-side con-
nector.
<Tester connections>
Ambient air temperature sensor
vehicle-side connector
HH1+
–
HH1-
<Standard values>
4.5
–
5.5 V
The measure-
ments meet
the standard
value: Go to
YES.
The measure-
ments do not
meet the stan-
dard value: Go
to NO.
Go to step 9.
Go to step 7.
7
Inspect for
short-circuit in
the ambient air
temperature
sensor har-
ness
Measure the resistance between
the terminals of the DCU 86P
vehicle-side connector and the
ground. (Use the signal check
harness)
<Tester connections>
DCU 86P vehicle-side connector
ATSS
–
Ground
ATS-
–
Ground
<Standard values>
The measure-
ments meet
the standard
value: Go to
YES.
The measure-
ments do not
meet the stan-
dard value: Go
to NO.
Go to step 8.
Repair or
replace the
harness.
Perform "After-
inspection
work" of
INFORMA-
TION section.
8
Inspect for dis-
connection in
the ambient air
temperature
sensor har-
ness
Measure the resistance of the
wire harness and sensor between
the DCU 86P vehicle-side con-
nector and the ambient air tem-
perature sensor.
1.
Connect the ambient air
temperature sensor connec-
tor.
2.
Connect the signal check
harness to measure the
resistance between the ter-
minals of the DCU 86P vehi-
cle-side connector.
<Tester connections>
DCU 86P vehicle-side connector
ATSS
–
ATS-
<Standard values>
25
C {77
F}: 3.7 k
The measure-
ments meet
the standard
value: Go to
YES.
The measure-
ments do not
meet the stan-
dard value: Go
to NO.
Go to step 9.
Repair or
replace the
harness.
Perform "After-
inspection
work" of
INFORMA-
TION section.
DTC: P0073
Ambient air temperature sensor - out of range
(Out of range high)
Inspection Procedure
Step
Action
Description
Judgement
Check
(Yes/No)
Yes
No
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...