DEF SCR SYSTEM (DCU)
5–237
1.
Set the starter switch to the "LOCK" position.
2.
Disconnect the coolant cut off valve (DEF tank heater valve) con-
nector.
3.
Use the electrical tester to measure the resistance of the terminals
of the coolant cut off valve (DEF tank heater valve).
NO
YES
1.
Twenty seconds after the engine has started, grasp the pipe down-
stream of the coolant cut off valve (DEF tank heater valve) and
check if the pressure drops.
NO
YES
10
Inspect the coolant cut off valve (DEF tank heater valve) unit
LDU
LDV
SAPH16F020400159
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
Coolant cut off
valve (DEF tank
heater valve) con-
nector
LDU
–
LDV
20
C {68
F}:
9.04
–
9.52
Do the measurements meet the standard value?
Go to step 11.
Replace the coolant cut off valve (DEF tank
heater valve).
Perform "After-inspection work" of INFOR-
MATION section.
11
Inspect the coolant cut off valve (DEF tank heater valve)
Did the pressure drop?
Go to step 12.
Replace the coolant cut off valve (DEF tank
heater valve).
Perform "After-inspection work" of INFOR-
MATION section.
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...