DEF SCR SYSTEM (DCU)
5–45
NO
YES
1.
Set the starter switch to the "LOCK" position.
2.
Disconnect the ambient air temperature sensor connector.
3.
Use the electrical tester to measure the resistance between the
terminals of the ambient air temperature sensor.
NO
YES
1.
Disconnect the external resistor connector.
2.
Use the electrical tester to measure the resistance between the
terminals of the external resistor.
Clean the ambient air temperature sensor
and install it properly. If damaged, replace
the ambient air temperature sensor.
Perform "After-inspection work" of INFOR-
MATION section.
Go to step 4.
4
Inspect the ambient air temperature sensor unit
HH1-
HH1+
SAPH16F020400033
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
Ambient air
temperature
sensor
HH1+
–
HH1-
25
C {77
F}:
1.7 k
Do the measurements meet the standard value?
Go to step 5.
Replace the ambient air temperature sensor.
Perform "After-inspection work" of INFOR-
MATION section.
5
Inspect the external resistor unit
ER-
ER+
SAPH16F020400034
Measurement
conditions
Tester
connections
Standard values
Starter switch:
LOCK
External resistor
ER+
–
ER-
2 k
Do the measurements meet the standard value?
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...