ENGINE CONTROL SYSTEM (J08E)
4–1226
P246F: Exhaust gas temperature sensor (DOC outlet) - rationality
INFORMATION [at engine running]
1. Technical description
•
The function of the DPR is to regenerate PM, which raises the exhaust gas temperature.
•
The value of the exhaust gas temperature sensor (DOC outlet) is used to control DPR regeneration.
<Description of malfunction>
•
The exhaust gas temperature cannot be correctly recognized.
2. DTC set condition
(1) DTC detection condition
•
At least 10 seconds has elapsed since engine was started.
•
Cumulative exhaust gas flow amount
≥
3 kg.
•
Cumulative exhaust gas flow amount of non-operating burner
≥
50 kg.
After the above:
•
Battery voltage is 10 V
–
16 V.
•
Engine speed
≥
500 r/min for at least 5 sec.
•
Difference between engine coolant temperature and intake temperature
≥
8
C {
14.4
F}.
•
Exhaust gas flow rate
≥
500 kg/h.
•
Engine speed
≥
1,750 r/min.
•
Fuel injection amount
≥
15 mm
3
/st
PTO
accelerator sensor
K95
(ET4+)
(ET2+)
(EXPS)
(ADG9)
(A
VC5)
LCG
KR4
(GND3)
(TEX3)
KUH
LCT
KUQ
(VOUT)
(GND)
KSK
KSL
(VCC)
KSJ
LCY
LCZ
LCY
LCG
KSF
LCT
KSK
KUH
KSJ
KUQ
KSE
KR4
LCY
LCG
KSF
LCT
KSK
KUH
KSJ
KUQ
KSE
KR4
(GND1)
(TEX1)
KSE
KSF
Differential
pressure
sensor
(VCC)
Engine
ECU
Exhaust gas
temperature
sensor
(DOC outlet)
Exhaust gas
temperature
sensor
(DOC inlet)
SAPH16F010300959
Summary of Contents for 238
Page 201: ...ENGINE CONTROL SYSTEM J08E 4 978 Harness disconnection or short circuit ...
Page 215: ...ENGINE CONTROL SYSTEM J08E 4 992 Malfunction of sensor 2 Malfunction of engine ECU ...
Page 301: ...ENGINE CONTROL SYSTEM J08E 4 1078 8 Estimated failure factors Malfunction of engine ECU ...
Page 709: ...DEF SCR SYSTEM DCU 5 143 8 Estimated failure factors DEF pump pressure sensor malfunction ...