User manual type 3245

SMARTCHARGER

7A

12V

Summary of Contents for SMARTCHARGER

Page 1: ...User manual type 3245 SMARTCHARGER 7A 12V ...

Page 2: ...arger will resume the charge cycle when it is reconnected to the mains To avoid overheating make sure there is sufficient room for circulation of air aro und the product when in use Do not cover it up The mains socket outlet used should always be easily accessible to facilitate im mediate removal of the products mains supply should an operational error occur during use The product contains hazardo...

Page 3: ... the specific battery Do not attempt to charge batteries that are not rechargeable WARNING As explosive gases may arise during charging lead acid batteries the charger and the battery should be placed in a well ventilated area during charging Avoid sparks and open flames Maintenance and warranty The charger is maintenance free If the unit itself or its cords are damaged it must be replaced by the ...

Page 4: ...t your service for many years to come provided the correct use and care of both the charger and the batteries Connect To charge a vehicle battery connect first the positive clip marked to the po battery pole then connect the other clip marked to the car s chassis away f the battery and fuel system fuel hoses fuel pump etc Place the temperature s on top of or close to the battery 2 Match Check that...

Page 5: ...s been fully discharged 15 7VDC max 1 5A recommended battery capacity 30 120Ah Gel batteries 14 4VDC max 7A recommended battery capacity 30 120Ah Power supply or float charger 13 7VDC max 6 5A Large batteries 14 7VDC max 7A recommended battery capacity 30 120Ah Quick start Check that the battery and charger specifications match Take the charger out from the case and connect the charger to the batte...

Page 6: ...charge until 10 5V 1 5A fast charge until 14 7V 20 C 14 7 Ch 0 2 GEL 1 6A low current precharge until 10 5V 7A fast charge until 14 4V 20 C 14 4 Ch 1 RECOND 1 6A low current precharge until 10 5V 7A fast charge until 14 7V 20 C 14 7 Ch 1 POWER SUPPLY Not Available Not Available Not INDICATION LED 0 Flashing 1S 1S LED 0 to 8 Shows the battery c LIMIT 0 5hrs start timer Safety timer 72 Mode programs...

Page 7: ...6 526 14025 7 ST GE TOP UP CHARGE RECOND PHASE FLOAT CHARGE PULSED FLOAT CHARGE rge until 20 C 14 7V 20 C Charge until 1 6A or 4hrs Not Available 13 7V 20 C 13 7V Short 7A pulses arge until 20 C 14 7V 20 C Charge until 0 25A or 4hrs Not Available 13 7V 20 C 13 7V Short 1 5A pulses harge 20 C 14 4V 20 C Charge until 1 6A or 4hrs Not Available 13 7V 20 C 13 7V Short 7A pulses harge 20 C 14 7V 20 C C...

Page 8: ... 60 60 60 60 80 80 80 80 100 100 100 100 LED 0 Flashing in 1 sec interval during softstart when the battery voltage is below 10 5V Pulse LED flashing in 7 sec intervals when in Float and Pulse charge phase Pulse LED flashing in 1 sec interval when battery is not connected All LEDs 0 100 are flashing simultaneously when in Recond phase after top up charge ...

Page 9: ...allinn Estonia 372 555 21 121 Mascot SWEDEN Box 177 N 1601 Fredrikstad 46 526 14025 9 Safety timer expired Wrong or defect battery Battery voltage remains low after precharge Wrong or defect battery Battery voltage above 16V Check battery type LED error codes Sequential flashing RED MODE LEDs R GEL Old sulfated Lead Acid batteries usually have a reduced capacity and may be difficult to charge The ...

Page 10: ... 3 to 4mV o C pr cell Efficiency at 100 load 230V 89 Switch frequency approx 65kHz Leakage current from battery with mains switched off 50 uA at 12V Protection Protected against reversed polarity and short circuit proof Prevents sparking Charge timer 4h Safety timer 72h Thermal protection Charging of wrong lower voltage battery pack e g 6V will be limited to 1 6A 0 25A small battery and terminated...

Page 11: ...rikstad 47 69 36 43 00 Mascot UK Bok 2090 Salisbury Wiltshire SP2 2BH 44 172 250 4853 Mascot DE BENELUX Hirschbergstr 28 7 D 74838 Limbach 49 628 795 140 Mascot DE CH AT Tettnanger Str 52 D 88239 Wangen 49 752 895 1677 Mascot BALTIC RUSSIA Taevakivi 15 13619 Tallinn Estonia 372 555 21 121 Mascot SWEDEN Box 177 N 1601 Fredrikstad 46 526 14025 11 ...

Page 12: ...sor on top of or close to the battery 2 Charge Connect the charger to the mains 3 Check status mode Charger will start automatically Check indication lights for status Use mode button to select preferred mode 4 Match Check that the battery and charger specifications match 1 NEGATIVE CLIP Check car user manual for where to connect www mascot no 230V Temperature sensor Positive clip Negative clip QU...