2-6
D
ELTA
/D
ELTA
XL/K
APPA
VF8
2 M
ONITOR
S
ETUP
Max.
Channels
Determines the number of waveform
channels and parameters displayed.
• Click on
4, 5, 6, 7,
or
8
NOTE:
The number of waveforms
depends on the software option you
have installed (see page 1-20 for a list
of options).
Bottom
Channel
Configures the bottom waveform channel
to display a waveform or 3 parameter
boxes.
Waveform
,
Parameters
ECG
Channels
Determines the number and format of
ECG waveforms displayed.
Click on the following settings:
•
ECG1
– Displays the primary ECG
waveform
•
ECG1 & 2
– Displays 2 waveforms
•
ECG1 & 2 & 3
– Displays 3
waveforms
•
Cascade
– Cascades ECG1 data
into second channel
ARR
Monitoring
Selects the Arrhythmia mode
(For detailed information, see page 9-5.)
• Select
OFF
to disable arrhythmia
monitoring.
• Select
FULL
to enable full arrhythmia
monitoring.
• Select
BASIC
to enable basic
arrhythmia monitoring.
ST
Monitoring
Enables and disables ST monitoring (for
detailed information, refer to chapter 10).
• Select
ON
to enable ST monitoring.
• Select
OFF
to disable ST monitoring.
RESP
Monitoring
Enables and disables respiration
monitoring (for detailed information, refer
to chapter 12).
• Select
ON
to enable respiration
monitoring.
• Select
OFF
to disable respiration
monitoring.
Display
Mode
Reduces Main screen clutter by
displaying only parameters associated
with a connected device (see
Parameter
Priority
on page 2-5).
• Select
Manual
to display all
parameters and assign them a
priority on the Parameter Priority
screen.
• Select
Automatic
to display active
parameters only.
Agent
Display
Displays an anesthetic agent parameter
box.
• Select
ON
to display agent.
• Select
OFF
to cancel display.
N2O Display
Displays N
2
O/O
2
parameter box.
NOTE
: This selection is ghosted unless
MultiGas or M module is
connected.
• Select
ON
to display N
2
O/O
2
.
• Select
OFF
to cancel display.
The Main Menu
Menu Item
Description
Available Settings
Summary of Contents for Infinity Delta
Page 76: ...2 26 DELTA DELTA XL KAPPA VF8 2 MONITOR SETUP This page intentionally left blank ...
Page 94: ...3 18 DELTA DELTA XL KAPPA VF8 3 NETWORK APPLICATIONS This page intentionally left blank ...
Page 118: ...5 16 DELTA DELTA XL KAPPA VF8 5 ALARMS This page intentionally left blank ...
Page 140: ...7 14 DELTA DELTA XL KAPPA VF8 7 RECORDINGS This page intentionally left blank ...
Page 166: ...8 26 DELTA DELTA XL KAPPA VF8 8 ECG AND HEART RATE This page intentionally left blank ...
Page 176: ...9 10 DELTA DELTA XL KAPPA VF8 9 ARRHYTHMIA MONITORING This page intentionally left blank ...
Page 188: ...10 12 DELTA DELTA XL KAPPA VF8 10 ST MONITORING This page intentionally left blank ...
Page 198: ...11 10 DELTA DELTA XL KAPPA VF8 11 EEG MONITORING This page intentionally left blank ...
Page 218: ...12 20 DELTA DELTA XL KAPPA VF8 12 RESPIRATION This page intentionally left blank ...
Page 256: ...14 22 DELTA DELTA XL KAPPA VF8 14 INVASIVE BLOOD PRESSURE This page intentionally left blank ...
Page 272: ...15 16 DELTA DELTA XL KAPPA VF8 15 CARDIAC OUTPUT C O This page intentionally left blank ...
Page 290: ...16 18 DELTA DELTA XL KAPPA VF8 16 CALCULATIONS This page intentionally left blank ...
Page 372: ...21 14 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS T NEONATAL FLOW SENSOR ...
Page 384: ...21 26 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS This page intentionally left blank ...
Page 526: ...A 6 DELTA DELTA XL KAPPA VF8 A GLOSSARY This page intentionally left blank ...
Page 584: ...B 58 DELTA DELTA XL KAPPA VF8 B TECHNICAL DATA This page intentionally left blank ...
Page 613: ...POD COMMUNICATION VF8 DELTA DELTA XL KAPPA C 29 ...