6-2
D
ELTA
/D
ELTA
XL/K
APPA
VF8
6 T
RENDS
Overview
The monitor stores trend data for all connected signals except for pressures labeled
P1a-d, P2a-d, P3a-d, which are automatically assigned as temporary labels when
pressure transducers are initially connected. You can request a trend recording or
report and execute a print screen of displayed trends. The monitor deletes all trend
data once the patient is discharged.
You can store a currently displayed trend screen in the Event Recall Database by
pressing the
Mark
fixed key on the front of the monitor. Manually and
automatically stored events are identified on an event summary bar at the top of the
trend display as outlined below:
Trend Table – An icon (
) over time line marks manually stored events
only; alarms and arrhythmia calls are not marked (see illustration on page 6-6)
Trend Graphs – A small yellow vertical line marks manually and
automatically stored events (see illustration on page 6-4).
For information on marking or storing events (including use of the
Mark
fixed key
and the Event Recall screen), see page 1-26.
Trend Setup
The Trend Setup menu allows you to customize trend functions.
To access the Trend Setup menu
1. Click on the
Menu
fixed key on the front of the monitor.
2. Click on
Monitor Setup
.
3. Click on
Trend Setup
to display the Trend Setup menu.
Summary of Contents for Infinity Delta
Page 76: ...2 26 DELTA DELTA XL KAPPA VF8 2 MONITOR SETUP This page intentionally left blank ...
Page 94: ...3 18 DELTA DELTA XL KAPPA VF8 3 NETWORK APPLICATIONS This page intentionally left blank ...
Page 118: ...5 16 DELTA DELTA XL KAPPA VF8 5 ALARMS This page intentionally left blank ...
Page 140: ...7 14 DELTA DELTA XL KAPPA VF8 7 RECORDINGS This page intentionally left blank ...
Page 166: ...8 26 DELTA DELTA XL KAPPA VF8 8 ECG AND HEART RATE This page intentionally left blank ...
Page 176: ...9 10 DELTA DELTA XL KAPPA VF8 9 ARRHYTHMIA MONITORING This page intentionally left blank ...
Page 188: ...10 12 DELTA DELTA XL KAPPA VF8 10 ST MONITORING This page intentionally left blank ...
Page 198: ...11 10 DELTA DELTA XL KAPPA VF8 11 EEG MONITORING This page intentionally left blank ...
Page 218: ...12 20 DELTA DELTA XL KAPPA VF8 12 RESPIRATION This page intentionally left blank ...
Page 256: ...14 22 DELTA DELTA XL KAPPA VF8 14 INVASIVE BLOOD PRESSURE This page intentionally left blank ...
Page 272: ...15 16 DELTA DELTA XL KAPPA VF8 15 CARDIAC OUTPUT C O This page intentionally left blank ...
Page 290: ...16 18 DELTA DELTA XL KAPPA VF8 16 CALCULATIONS This page intentionally left blank ...
Page 372: ...21 14 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS T NEONATAL FLOW SENSOR ...
Page 384: ...21 26 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS This page intentionally left blank ...
Page 526: ...A 6 DELTA DELTA XL KAPPA VF8 A GLOSSARY This page intentionally left blank ...
Page 584: ...B 58 DELTA DELTA XL KAPPA VF8 B TECHNICAL DATA This page intentionally left blank ...
Page 613: ...POD COMMUNICATION VF8 DELTA DELTA XL KAPPA C 29 ...