![Dräger Infinity Delta Instructions For Use Manual Download Page 281](http://html.mh-extra.com/html/drager/infinity-delta/infinity-delta_instructions-for-use-manual_2526779281.webp)
P
HYSIOLOGICAL
C
ALCULATIONS
(H
EMO
/O
XY
/V
ENT
C
ALCULATIONS
)
VF8
D
ELTA
/D
ELTA
XL/K
APPA
16-9
Lab Data on Calculations Screen
To display laboratory data on the Hemo/Oxy/Vent Calculations screen, proceed as
follows:
1. Sample and analyze the patient’s blood.
2. Press the
Fast Access
fixed key on the monitor’s front panel.
3. Click on
Calculations
to display the Hemo/Oxy/Vent Calculations menu.
Lab data input parameters appear on the right.
4. Click on
Capture Values
. A message at the top of the main screen indicates
when new lab data is available.
5. Click on
Capture Labs
to capture blood gas values.
6. Click on
Calculate or Results
. The Calculations screen appears with updated
derived parameters.
1
Time/date stamp indicating the time the
monitor receives data. Labeled
according to the following criteria: test
time – the time and date are generated
by blood analysis device and sent with
the lab results.
Arrival time – the time and date are
generated by the monitor; no test time is
sent with the lab results.
2
Displays current values (appears
ghosted until requested data is available)
3
A ‘greater than’ symbol (>) indicates that
the number of characters or digits
exceeds the available display space.
4
Parameter labels, values and units of
measure.
Summary of Contents for Infinity Delta
Page 76: ...2 26 DELTA DELTA XL KAPPA VF8 2 MONITOR SETUP This page intentionally left blank ...
Page 94: ...3 18 DELTA DELTA XL KAPPA VF8 3 NETWORK APPLICATIONS This page intentionally left blank ...
Page 118: ...5 16 DELTA DELTA XL KAPPA VF8 5 ALARMS This page intentionally left blank ...
Page 140: ...7 14 DELTA DELTA XL KAPPA VF8 7 RECORDINGS This page intentionally left blank ...
Page 166: ...8 26 DELTA DELTA XL KAPPA VF8 8 ECG AND HEART RATE This page intentionally left blank ...
Page 176: ...9 10 DELTA DELTA XL KAPPA VF8 9 ARRHYTHMIA MONITORING This page intentionally left blank ...
Page 188: ...10 12 DELTA DELTA XL KAPPA VF8 10 ST MONITORING This page intentionally left blank ...
Page 198: ...11 10 DELTA DELTA XL KAPPA VF8 11 EEG MONITORING This page intentionally left blank ...
Page 218: ...12 20 DELTA DELTA XL KAPPA VF8 12 RESPIRATION This page intentionally left blank ...
Page 256: ...14 22 DELTA DELTA XL KAPPA VF8 14 INVASIVE BLOOD PRESSURE This page intentionally left blank ...
Page 272: ...15 16 DELTA DELTA XL KAPPA VF8 15 CARDIAC OUTPUT C O This page intentionally left blank ...
Page 290: ...16 18 DELTA DELTA XL KAPPA VF8 16 CALCULATIONS This page intentionally left blank ...
Page 372: ...21 14 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS T NEONATAL FLOW SENSOR ...
Page 384: ...21 26 DELTA DELTA XL KAPPA VF8 21 RESPIRATORY MECHANICS This page intentionally left blank ...
Page 526: ...A 6 DELTA DELTA XL KAPPA VF8 A GLOSSARY This page intentionally left blank ...
Page 584: ...B 58 DELTA DELTA XL KAPPA VF8 B TECHNICAL DATA This page intentionally left blank ...
Page 613: ...POD COMMUNICATION VF8 DELTA DELTA XL KAPPA C 29 ...