Synergy 100 Installation Guide (v16.10-S100)
Preliminary Cabling and Check • 3–3
1. Ensure that you have the correct
8-pin
shielded Telco cable, with
8-pin
connectors at
each end. Because of their small size, all Telco connectors look quite similar.
2. Using an 8-pin shielded Telco cable, connect the communications port labeled
SYNERGY PANEL
(on the electronics frame) to the communications port labeled
SYNERGY
(on the rear of the Synergy 100 panel).
Please note:
•
The maximum cable length is 1000 feet (305 meters).
•
The cable must be run in accordance with good engineering practice. Ensure that there is
sufficient room for the cable and that enough slack is left in the cable run to permit long,
gentle bends. Always install cables so that they will not be subjected to physical abuse.
•
The Synergy 100 panel can also be connected to the frame via an existing GVG 100/110
control cable or an existing RVS 210/216 control cable. Refer to the section “
” on page 2–12 for more details.
Remote Aux Panel Cabling
This section provides instructions for cabling
Remote Aux Panels
. If your system includes remote
Aux Bus panels, one serial cable is shipped with each panel. There are two types of cable available:
•
Aux panel cables with standard 10 meter lengths.
•
Non-standard cables with lengths specified by the customer.
For standard length cables, refer to the packing list provided with your switcher; the length will be
given there. For custom length cables, the length is given on a label attached to the cable.
Once you have located the appropriate cables for each remote Aux panel, make the connections
according to the following figure:
Remote Aux Panel Interconnection
Use the following procedure to install the control cables between the frame and each remote Aux
panel:
1. Ensure that you have the correct
6-pin
shielded Telco cable, with
6-pin
connectors at
each end. Because of their small size, all Telco connectors look quite similar.
Important
The cable for connecting the Synergy 100 Control Panel to the
Synergy 1 Frame is not wired as a standard CAT5 ethernet cable. If
you need a cable of a specific length, contact your Ross Video
Representative for ordering information.
J5
MAIN
J1
ECHO
J4
POWER
J2
GPI
+5 V REG
1 A
Remote Aux Panel
To connector J5 on
the next Aux Panel
in the chain, or no
connection if the last
panel in the chain.
SYNERGY
PANEL
AUX
PANEL
Frame
Содержание Synergy 100
Страница 1: ...Ross Video Limited Installation Guide Software Issue 16 10 S100...
Страница 10: ......
Страница 16: ...vi Contents Synergy 100 Installation Guide v16 10 S100...
Страница 66: ...2 32 Installation Synergy 100 Installation Guide v16 10 S100...
Страница 88: ...5 6 Using the Menu System Synergy 100 Installation Guide v16 10 S100...
Страница 100: ...6 12 BNC Configuration and Check Synergy 100 Installation Guide v16 10 S100...
Страница 134: ...7 34 Communication Setup Synergy 100 Installation Guide v16 10 S100...
Страница 170: ...8 36 Additional Installation Setups Synergy 100 Installation Guide v16 10 S100...
Страница 186: ...9 16 Completing Setup Synergy 100 Installation Guide v16 10 S100...
Страница 208: ...10 22 Appendix A Specifications Synergy 100 Installation Guide v16 10 S100...
Страница 216: ...11 8 Appendix B Hardware Options Synergy 100 Installation Guide v16 10 S100...
Страница 234: ...GL 4 Glossary of Terms Synergy 100 Installation Guide v16 10 S100...
Страница 246: ...IX 12 Index Synergy 100 Installation Guide v16 10 S100...