7–30 • Communication Setup
Synergy 100 Installation Guide (v16.10-S100)
~
RS422
— Use this option if the device uses the RS-422 communications
protocol.
•
Press the right
SEL
button to accept the new settings.
8. If you are using the
Contribution
protocol, you must set up the extra options for your
serial tally interface device. Complete the procedure in the section “
” on page 7–30 to finish setting up your serial tally interface
device. If you are not using the Contribution protocol, proceed to the next step.
9. If you are using the
Look Ahead Serial Tally
protocol, you must set up the extra
options for your serial interface device. Complete the procedure in the section “
Ahead Serial Tally Extra Options
” on page 7–32 to finish setting up your serial tally
interface device. If you are not using the
Look Ahead Serial Tally
protocol, proceed to
the next step.
10. Press
MENU
to display the
Installation Change Screen
.
11. Accept or cancel these changes as follows:
•
Press
0. Confirm
to accept the changes.
•
Press
1. Cancel
to exit the menus safely, without making any changes. The system
returns to the previously stored settings.
This completes the procedure for setting up a serial tally interface device on a peripheral port.
Contribution Serial Tally Extra Options
The
Contribution
protocol has extra options that
must
be setup to properly communicate with a serial
tally interface device.
Use the following procedure to set up the Extra Options for your serial tally interface device:
1. Ensure that the
Communication Menu
is displayed and that menu item
0. Port
is set to
the serial tally interface device you want to set up the extra options for.
2. Assign a specific serial tally interface device to the selected peripheral port as follows:
•
Press
8. Option
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
)
buttons to select
Rate
.
•
Press the right
SEL
button to accept the new settings.
•
Press
9. Rate
.
•
Use the
UP ARROW
or
DOWN ARROW
(
1
or
10
)
buttons to select the length of
time (in fields) between update messages sent by Synergy to the serial tally
interface device.The default value of
26
is the recommended setting, but you can
choose
any
value between
2
and
60
, inclusive.
•
Press the right
SEL
button to accept the new settings.
Important
True RS-232 is only available on
Peripheral Port 2
. However, you
can connect an audio board using RS-232 protocol to
Peripheral Port
1
if
the
Protocol
heading is set to
RS-422
, and an RS-422-to-RS-232
converter is used.
Note
When menu item
8. Option
is set to
Rate
, menu item
9. Reserved
changes to
9. Rate
.
Содержание Synergy 100
Страница 1: ...Ross Video Limited Installation Guide Software Issue 16 10 S100...
Страница 10: ......
Страница 16: ...vi Contents Synergy 100 Installation Guide v16 10 S100...
Страница 66: ...2 32 Installation Synergy 100 Installation Guide v16 10 S100...
Страница 88: ...5 6 Using the Menu System Synergy 100 Installation Guide v16 10 S100...
Страница 100: ...6 12 BNC Configuration and Check Synergy 100 Installation Guide v16 10 S100...
Страница 134: ...7 34 Communication Setup Synergy 100 Installation Guide v16 10 S100...
Страница 170: ...8 36 Additional Installation Setups Synergy 100 Installation Guide v16 10 S100...
Страница 186: ...9 16 Completing Setup Synergy 100 Installation Guide v16 10 S100...
Страница 208: ...10 22 Appendix A Specifications Synergy 100 Installation Guide v16 10 S100...
Страница 216: ...11 8 Appendix B Hardware Options Synergy 100 Installation Guide v16 10 S100...
Страница 234: ...GL 4 Glossary of Terms Synergy 100 Installation Guide v16 10 S100...
Страница 246: ...IX 12 Index Synergy 100 Installation Guide v16 10 S100...