Synergy 100 Installation Guide (v16.10-S100)
Appendix A. Specifications • 10–21
Notes:
(*1) LED indicates the current group setting. Only one LED in the first eight switches can be
ON at a time. A panel that has never been programmed may have all eight LEDs OF
F
,
until it is programmed to one of the eight possible GPI groups. It is possible to set the
group to off by pressing the current group button (all 8 buttons will flash when group is
set to OFF in this way).
(*2) Changing the shift setting locally has no lasting effect. The main panel and frame
software sets this value automatically to be the same as the panel during normal
operations. The LED displays the state of this option when first entering program mode.
The Remote Panel does not support special modes of shifted cross-points (such as
Reverse Shift, etc.).
Note: Shift Indication is not present in GPI modes prior to remote panel firmware
version 2.14.
(*3) To start a power-up diagnostic hold the button while applying power. Release button
after panel has powered up. Tests are automatic except the Button test. In the button test,
press the buttons and verify that the corresponding LEDs light.
(*4) DUART test requires special loop-back tester cables. Contact Technical Support for
details.
(*5) In the EEPROM and DUART tests, the “Active” LED indicates Test Failed if the
“Active” LED remains lit. In the same tests, the Xpt 1 (Black) LED indicates Test
Passed when lit.
(*6) Although the panel’s rights to Aux Buses 1 and 2 can be modified, it will have no effect
on the switcher as Aux Buses 1 and 2 are not implemented.
DVE
SEND
Select DVE
Send
Clean
Feed
Select Clean
Feed
Switch to GPI program mode
and LED will start flashing.
Switch to
Assignment
Program mode
and
LED will stop
flashing.
Switch to
Assignment
Program mode and
LED will stop
flashing.
Program
Select Program
Send software version message to
main panel
Send software
version message to
main panel
Send software
version message to
main panel
Active
LED
Indicates
selected Aux Xpt
is used in
Program output
Flashing
Flashing (along
with Clean Feed)
Flashing (along with
a flashing Clean
Feed and flashing
Button #9)
Test Fail Status
(*5)
Aux Panel Programming Mode Button Assignment
Button/
LED
Normal
Mode
Program Mode
Bus Assignment
Program
Mode
GPI Offset
Program Mode
GPI Status
Power Up
Diagnostics
Содержание Synergy 100
Страница 1: ...Ross Video Limited Installation Guide Software Issue 16 10 S100...
Страница 10: ......
Страница 16: ...vi Contents Synergy 100 Installation Guide v16 10 S100...
Страница 66: ...2 32 Installation Synergy 100 Installation Guide v16 10 S100...
Страница 88: ...5 6 Using the Menu System Synergy 100 Installation Guide v16 10 S100...
Страница 100: ...6 12 BNC Configuration and Check Synergy 100 Installation Guide v16 10 S100...
Страница 134: ...7 34 Communication Setup Synergy 100 Installation Guide v16 10 S100...
Страница 170: ...8 36 Additional Installation Setups Synergy 100 Installation Guide v16 10 S100...
Страница 186: ...9 16 Completing Setup Synergy 100 Installation Guide v16 10 S100...
Страница 208: ...10 22 Appendix A Specifications Synergy 100 Installation Guide v16 10 S100...
Страница 216: ...11 8 Appendix B Hardware Options Synergy 100 Installation Guide v16 10 S100...
Страница 234: ...GL 4 Glossary of Terms Synergy 100 Installation Guide v16 10 S100...
Страница 246: ...IX 12 Index Synergy 100 Installation Guide v16 10 S100...